Dialog
Dialog Support   >   "How Do I...?" Series   >   Pharmaceuticals & Health Devices
Dialog "How Do I...?" - Pharmaceuticals & Health Devices

Find Drug or Device Recall Notices Issued by a Particular Company in the U.S.?

TOPIC: The FDA can request that a manufacturer recall a product and manufacturers usually comply. In some cases, manufacturers recall defective drugs without an FDA request. According to the FDA, recalls fall into three categories:

  • Class I: Dangerous or defective drugs that could cause serious health problems or death
  • Class II: Drugs that might cause a temporary health problem or pose a remote threat of a serious problem
  • Class III: Drugs that are unlikely to cause a health problem, but violate FDA labeling or manufacturing regulations

In many cases, drug recalls are the result of a problem in manufacturing or labeling that affects only a specific "batch" or "lot number" of a drug. In this case, the manufacturer recalls only the drugs that have the defect. Note that the FDA does not have the authority to "order" that a drug be taken off the market. The agency can only order a recall in the case of a threat to human life from infant formula, a medical device or a human-tissue product such as blood. Recall notices as reported in the weekly FDA Enforcement Report are provided in DIOGENES® FDA Regulatory Updates* (File 158). DIOGENES contains data on drugs as reported to the FDA by drug manufacturers, individuals, health professionals and medical studies.

In this example you want to find Class III recalls of Medtronic drugs in the years 2005 and 2006.

*Covers 1976-2011.

 

COMMAND SUMMARY

BEGIN 158
SELECT RECALL? AND CLASS()III
SELECT MEDTRONIC/CO
SELECT S1 AND S2
SELECT S3/2005:2006
TYPE S4/6/1-5
TYPE S4/9/1


HOW TO...



1. BEGIN File 158 to search for FDA recall notices.

2. SELECT the type of document you want (e.g., recalls) limited to the class of recall.

3. Limit to the company (/CO) you want to see recalls for, combine sets and limit to current year(s).



?b 158

File 158:DIOGENES(R) 1976-2006/Jun W4
       (c) 2006 DIOGENES
 
      Set  Items  Description
      ---  -----  -----------
?SELECT RECALL? AND CLASS()III
           44725  RECALL?
         1398035  CLASS
           20028  III
            9151  CLASS(W)III
      S1    8867  RECALL? AND CLASS()III

?SELECT MEDTRONIC/CO
      S2   76203  MEDTRONIC/CO

?S S1 AND S2
            8867  S1
           76203  S2
      S3      43  S1 AND S2

?S S3/2005:2006
              43  S3
            1523  PY=2005 : PY=2006
      S4       6  S3/2005:2006




4. TYPE
all records to see any Class III recalls Medtronic is involved in.

 

 


?T S4/6/ALL
 
  4/6/1  
02532872   DIOGENES RECORD NUMBER: E0149733
 Medtronic Paceart   CLASS    III  RECALL 02/??/06:  Software.
  WORD COUNT:            204
 
  4/6/2  
02532871   DIOGENES RECORD NUMBER: E0149732
 Medtronic Puerto Rico   CLASS    III  RECALL 03/??/06:  Neurostimulator.
  WORD COUNT:            190
 
  4/6/3  
02532668   DIOGENES RECORD NUMBER: E0149393
 Medtronic Navigation   CLASS    III  RECALL 02/01/06:  Knee Kit.
  WORD COUNT:             78
 
  4/6/4  
02532077   DIOGENES RECORD NUMBER: E0148770
  Medtronic  Sofamor  Danek Instrument Manufacturing CLASS   III   RECALL 12/01/05:  Screw Driver.  
  WORD COUNT:             59
 
  4/6/5  
02531973   DIOGENES RECORD NUMBER: E0148498
 Medtronic MiniMed CLASS   III   RECALL 04/27/05: Instructional Booklet.  
  WORD COUNT:            123
 
  4/6/6  
02530508   DIOGENES RECORD NUMBER: E0146547
 Medtronic Neurosurgery   CLASS    III  RECALL 02/28/05:  Medical Scopes.
  WORD COUNT:             74


5. TYPE
any complete records you want to view in more detail using Format 9.

The record shows recall title, date and company affected.



?t s4/9/5

  4/9/5  
DIALOG(R)File 158:DIOGENES(R)
(c) 2006 DIOGENES. All rts. reserv.
 
02531973   DIOGENES RECORD NUMBER: E0148498
 
Medtronic MiniMed CLASS   III   RECALL 04/27/05: Instructional Booklet.  
  BRAND  NAME: "Fine Tuning Your Pump" booklt provided with model MMT-515 &
  MMT-715 insulin infusion pumps.
  DRUG NAME: Instructional booklet.
  COMPANY NAME:  Medtronic   MiniMed, Northridge, CA.
  SOURCE: FDA ENFORCEMENT REPORT 11/23/2005.
  PUBLICATION DATE: April 27, 2005 (  20050427)   )
  RECORD TYPE: Fulltext
  WORD COUNT:            123  (Short)
  DOCUMENT TYPE:   DEVICE  (DEV)
  LANGUAGE: English
  PRODUCT
  "Fine  Tuning  Your Pump" booklet provided with Model MMT-515 and MMT-715 Insulin Infusion Pumps,  Recall   # Z-0162-06
  CODE All models shipped between October 1, 2004 and April 5, 2005.
  RECALLING   FIRM/MANUFACTURER
  Medtronic  MiniMed,  Northridge,  CA,  by  letter on April 27, 2005. Firm initiated  recall is ongoing.
  REASON
  The text description of how to perform insulin sensitivity testing and associated  worksheet included in the booklet that is shipped with the Paradigm  515 and Paradigm 715 insulin pumps contained a basic flaw in that the  blood  glucose  after  the correction should be compared to the target glucose  and  it  says  compare to the beginning blood glucose in the procedure.
  VOLUME OF PRODUCT IN COMMERCE Approximately 14,560
  DISTRIBUTION Nationwide, Bahamas, Bermuda, Canada, Mexico, and PR

RELATED HOW DO I...? SOLUTIONS

 

NEED HELP?

Contact the Dialog Knowledge Center
Within North America 1 800 3 DIALOG (334 2564)
Outside North America 00 800 33 DIALOG (33 34 2564)
Web Form www.dialog.com/contacts/webform

Stock #: 54332; Last modified: 2 Nov 2012



You are viewing the
Dialog Classic Version

Click below to view the
DialogLink 5 Version
Dialog Home   |   About Dialog   |   Site Search
Copyright Notices   |   Terms of Use   |   Privacy Statement